Double wall isulated stainless steel flue

Single wall stainless steel adapter

Adapter

This component is necessary for the isolated single flue connection to the double wall flue. Can be connected both to a Tee and the straight section.

Single wall stainless steel flue pipe rain cap

Rain cap

Rain cap normally protects the chimney from rainfall and falling, flying objects and creatures to get into the flue.

Condensate tray of the double wall stainless steel flue pipes

Condensate tray

Component, which is for condensate and rainfall removal from chimney. If the flue length of less than 7m, then cleaned with the trap discharges condensate is optional.

Double wall stainless steel flue pipe cone

Cone

Flue final conclusion. Conical shape serves to improve traction.

Double wall stainless steel flue pipe elbow 15

Elbow 15

If the design of the building does not allow the installation of flue straight, then with elbow 15 degree may be designed chimney in any direction.

Double wall stainless steel flue pipe elbow 45

Elbow 45

If the design of the building does not allow the installation of flue straight, then with elbow 45 degree may be designed chimney in any direction.

Double wall stainless steel flue pipe elbow 90

Elbow 90

If the design of the building does not allow the installation of flue straight, then with elbow 45 degree may be designed chimney in any direction.

Tee connection of the stainless steel flue pipe connection

Tee conection

It is used to attach horizontal flue or heating device to chimney.

Inspection with condensate tray + tee connection

Inspection with the condensate tray + Tee

Inspection is a flue phase, which is used for cleaning soot from chimney. Normally, to the base of inspection is attached condensate tray. Most often the next step after the inspection followed by the Tee connection

Stainless steel flue pipe inspection with lid

Inspection with lid

Inspection is a flue phase, which is used for cleaning soot from chimney. Normally, to the base of inspection is attached condensate tray. Hermetically obscuring the cleaning hatch.

Double wall insulated steel flue pipe inspection lid

Inspection lid

Hermetically obscuring the cleaning hatch.

Locking band of the double wall insulated stainless steel flue pipes

Locking band

Each stage of flue is connected with locking band. Locking band can be used repeatedly, so the flue assembly and disassembly is much easier as opposed to where the flue sections are joined together with rivets.

Length of the double wall insulated stainless steel flue pipes

Length

Standard length 500mm and 1000mm. In some cases, may order non-standard length.

Lengths of the double wall stainless steel flue pipes

Sections of Length

Can be mounted either vertically or horizontally.

Tee connection of the double wall steel flue pipes with adapter

Tee with adapter

It is used to attach a heating device.